To learn more about our EO Q-switched Nd:YAG MedLite® laser series, contact HOYA ConBio™ today.
“It is widely known that this Q-switched Nd:YAG laser system is the overall best tool for tattoo removal, but I mainly appreciate its speed and versatility. Low fluence green is a good option for removing the benign pigmented lesions of photoaging. Scars, especially acne scars, usually improve over several months after moderate fluence treatment at 1064 nm. Clinically, this laser is a workhorse.”
R. Rox Anderson, M.D.
Director, Wellman Research Center, Harvard Medical School
Boston, MA
The MedLite® laser provides aesthetic improvements with the reliability and safety you can expect from HOYA ConBio™, a global leader in medical lasers for more than 25 years. In applications ranging from wrinkle and acne scar reduction, non-ablative skin resurfacing, tattoo removal, removal of pigmented lesions (sun spots) and hair removal, HOYA ConBio™ aesthetic medical lasers have earned the trust of doctors and patients alike, worldwide. To learn more about our RevLite™ and MedLite® EO Q-switched Nd:YAG lasers, contact HOYA ConBio™ today.
MedLite® C Series EO Q-switched Aesthetic Medical LasersFor over a quarter century, HOYA ConBio™ has produced state-of-the-art lasers for the medical community. The MedLite® laser was first introduced in 1992 and subsequent enhanced models are now used by physicians worldwide. This efficient, versatile and cost-effective laser has helped progressive medical practices rise to the next level of success. If you would like to learn more about how MedLite® C Series laser products can enrich your practice, contact HOYA ConBio™ today.
You may also view the accessories available for use with our medical laser products.
| MedLite® C3 | MedLite® C6 | |
![]() |
![]() |
Black, Dark Blue and Red Ink Tattoo Removal |
![]() |
![]() |
Epidermal and Dermal Pigmented Lesion Removal |
![]() |
![]() |
Vascular Lesion Treatment |
![]() |
Wrinkle and Acne Scar Reduction | |
![]() |
Hair Removal/Reduction | |
![]() |
Sky Blue and Green Ink Tattoo Removal |
A MedLite® C Series laser is a safe, premium-engineered, easy-to-use aesthetic laser designed for versatility and effectiveness in a wide variety of applications. HOYA ConBio™ has made continual improvements to the MedLite® laser since its introduction in 1992, increasing its power output, reducing its size, and introducing valuable features to maintain high levels of physician and patient satisfaction. Today, the MedLite® Series is best known for its PhotoAcoustic effect, a combination of high power and nanosecond pulse widths that deliver peak energy throughout the layers of the epidermis faster than the normal relaxation time of the tissue. The result is a safe, effective way to harness peak power.
Because of the versatility that comes with multiple wavelengths and nanosecond Q-switched technology, doctors are able to perform a wide range of aesthetic laser treatments, from wrinkle and acne scar reduction, multi-color tattoo removal, pigmented lesion (sun spot) removal, hair removal, and vascular lesion treatments.

View a chart of the many wavelengths available with MedLite® C Laser Series.
A MedLite® C Series EO Q-switched Nd:YAG laser is a valuable addition to any aesthetic medical practice. With a powerful, compact and reliable medical laser, physicians can offer patients a greater range of treatments, regardless of skin type. The MedLite® can help attract new patients — while expanding services available to existing patients. Both the C3 and C6 MedLite® lasers offer 1064 nm and 532 nm wavelengths. With the use of MultiLite Dye Laser Handpieces, compatible with the MedLite® C6, the Polymer Dye HP can convert the 532 nm wavelength to both 585 nm and 650 nm, for a total of four possible wavelengths across a variety of procedures.

View the absorption spectrum for Melanin and Hemoglobin.
The MedLite® C Series EO Q-switched laser utilizes the latest in multi-wavelength, articulated-arm-delivered laser technology. Representing the next generation of Q-switched technology, the MedLite® uses an electro-optic (EO) high-speed shutter to produce nanosecond pulse widths. Peak energy is dispersed throughout the epidermis faster than the relaxation time of the healthy tissue. The result is a PhotoAcoustic Therapy effect, a safe, effective way to deliver energy precisely where it is needed. Contact us if you would like to learn more about the PhotoAcoustic action or any aspect of our MedLite® C Series lasers.
MultiLite Dye Laser Handpieces for Four WavelengthsThe HOYA ConBio™ MultiLite Dye Laser Handpieces are designed for the MedLite® C6 and RevLite™ lasers. These dye-impregnated polymer rods convert the 532 nm wavelength to either 585 nm or 650 nm, providing a total of four wavelengths and significantly expanding treatment options for patients.
The backbone of the MedLite® laser C series is the Nd:YAG crystal, a solid-state material used for years in scientific and medical communities. The HOYA ConBio™ MedLite® C3 and C6 lasers have the added benefit of being EO Q-switched, the next generation of Q-switching that produces high-speed repetition pulse durations.
AimLite™ (Aiming Beam Technology)The AimLite™ system provides physicians with assistance in performing laser skin resurfacing and other procedures in discrete and/or delicate areas such as near the mouth and eyes. Specifically, the AimLite™ produces a red aiming beam that is co-linear with the treatment beam, enabling the physician to achieve accurate positioning of the beam for best results.
By storing energy between pulses, an EO Q-switched laser is able to deliver a more effective pulse output than traditional lasers. The EO (electro-optic) Q-switch acts as an efficient high-speed shutter, delivering nanosecond pulse durations. This technology allows the MedLite® to produce peak power of over 200 megawatts with a 5 to 20 nanosecond pulse width. The result – a high power laser that delivers aesthetic solutions with a PhotoAcoustic effect.
The MedLite® C6 beam profile is a flat-top, smooth, evenly-calibrated beam without uneven spikes of energy typical in other lasers. As a result, the energy is delivered in extremely even pulse widths, targeting the chromophore with accuracy and efficiency, minimizing any damage to the epidermis.
PurpuraLite™ Chromophore Clearing Device PurpuraLite™, our exclusive chromophore clearing device, minimizes purpura that typically results from certain aesthetic laser treatments. Exclusive to HOYA ConBio™, this system temporarily “empties” the fine blood vessels under the treatment area to eliminate the “red” chromophore that typically creates a purpuric response. This accessory is standard with all new MedLite® C Series lasers and is an option for all MedLite® C Series lasers currently in use.
| Laser Parameters | |
| Laser Medium | Nd:YAG & Dye Impregnated Polymers |
| Operating Parameters | EO Q-switched |
| Nominal Delivered Energy at end of Articulated Arm with no Handpiece | |
| 1064 nm | 1.0 Joule |
| 532 nm | 400 mJ |
| Converted Wavelengths | |
| 585 nm | 250 mJ |
| 650 nm | 150 mJ |
| Nominal Pulse Energy Density at: | |
| 1064 nm | 12.0 J/cm2 @ 3.0 mm spot size |
| 532 nm | 5.0 J/cm2 @ 2.0 mm spot size |
| 585 nm | 8.0 J/cm2 @ 2.0 mm spot size |
| 650 nm | 4.5 J/cm2 @ 2.0 mm spot size |
| Pulse Width | 5-20 ns |
| Treatment Repetition Rate | Single shot, 1, 2, 5, and 10 Hertz |
| Aiming Beam | |
| 650 nm | <1mw 3 intensity levels |
| Spot Size | |
| 1064 nm | 3, 4, 6 & 8 mm |
| 532 nm | 2, 3, 4 & 6 mm |
| Cooling | Closed Cycle Water to Air Heat Exchanger |
| Physical Parameters | |
| Input Power | 220 V, Single Phase, 8 Amps or 110 V, Single Phase, 15 Amps |
| Weight | 127 Pounds (58 kg) |
| Size | 28.5” (72.5 cm) depth 12” (30.5 cm) width 31.8” (81 cm) height without articulated arm 44.5” (113 cm) |
| Optical Delivery | Articulated Arm |
| Laser Parameters | |
| Laser Medium | Nd:YAG |
| Operating Parameters | EO Q-switched |
| Nominal Delivered Energy at end of Articulated Arm with no Handpiece | |
| 1064 nm | 450 mJ |
| 532 nm | 200 mJ |
| Maximum Pulse Energy Density at: | |
| 1064 nm | 12.0 J/cm2 @ 2.0 mm spot size |
| 532 nm | 5.0 J/cm2 @ 2.0 mm spot size |
| Pulse Width | 5-7 ns |
| Treatment Repetition Rate | Single shot, 1, 2, 5, and 10 Hertz |
| Spot Sizes | |
| 1064 nm | 2, 3, 4, 6 & 7 mm |
| 532 nm | 1.5, 2, 3, 4, & 6 mm |
| Cooling | Closed Cycle Water to Air Heat Exchanger |
| Physical Parameters | |
| Input Power | 220 V, Single Phase, 8 Amps or 110 V Single Phase, 15 Amps |
| Weight | 127 Pounds (58 kg) |
| Size | 28.5” (72.5 cm) depth 12” (30.5 cm) width 31.8” (81 cm) height without articulated arm – 44.5” (113 cm) |
Specifications subject to change without notice.



If you would like to learn more about EO Q-switched MedLite® C Series laser technology, contact HOYA ConBio™ today.